  Industrial Glass
  Heat Exchanger
  Valves
  Column Components
  Pipe Components
   
   
Column Components

COLUMN SECTIONS


Column can be constructed either by using pipe sections with Support plates or using Column Sections with Packing supports.

Column sections are provided with fused shelf where packing support can rest.

Sr No

DN

L

L1

Minimum packing Size

Usual packing Size

 CS3/1000

80

1000

75

9

12

 CS4/1000

100

1000

75

12

15

 CS6/1000

150

1000

75

15

25

 CS6/1500

150

1500

100

15

25

 CS9/1000

225

1000

100

20

25

 CS9/1500

225

1500

100

20

25

 CS12/1000

300

1000

100

25

25

 CS12/1500

300

1500

100

25

25

 CS16/1000

400

1000

150

25

25

 CS16/1500

400

1500

150

25

25

 CS18/1000

450

1000

150

25

25

 CS18/1500

450

1500

150

25

25

 CS24/1000

600

1000

200

40

40

   

COLUMN SECTIONS WITH THERMOMETER BRANCH

Above column sections can be provided with a thermometer branch below the packing shelf at 20° slope

Sr No

DN

DN1

L

L1

d

 CST3/1000

80

25

1000

125

50

 CST4/1000

100

25

1000

125

75

 CST6/1000

150

25

1000

125

125

 CST6/1500

150

25

1500

125

125

 CST9/1000

225

25

1000

150

175

 CST9/1500

225

25

1500

150

175

 CST12/1000

300

25

1000

150

250

 CST12/1500

300

25

1500

150

250

 CST16/1000

400

25

1000

200

250

 CST16/1500

400

25

1500

200

350

 CST18/1000

450

25

1000

200

400

 CST18/1500

450

25

1500

200

400

 CST24/1000

600

25

1000

250

450

   







 

 





SUPPORT

Sr No

DN

L

Cross Section Area

Max. Load Kgs.

Minimum Packing Size

Type

 CP3

80

10

45%

10

12

A

 CP4

100

12

50%

15

15

A

 CP6

150

55%

30

25

A

 CP9

225

19

60%

50

25

A

 CP12

300

19

65%

75

25

A

  

 HD16

400

70

70%

150

25

B

 HD18

450

70

70%

200

25

B

 HD24

600

95

70%

300

40

B

   

 





REFLUX DIVIDER

add DN DN1 DN2 column

Reflux dividers are used to take off the distillate from the column. Usually a valve is to be fitted on distillate outlet which controls the reflux coarsely.

Sr No

DN

DN1

DN2

L

L1

Free Cross Section Cm 2

Max. Product L/hr

 RDA3

80

25

25

200

100

20

300

 RDA4

100

25

25

250

150

50

500

 RDA6

150

25

25

250

150

100

700

 RDA9

225

25

25

375

150

150

900

 RDA12

300

25

25

375

150

250

1100

 RDA16

400

40

40

500

200

350

1300

 RDA18

450

40

40

600

275

500

1500

   

DN2 is used for insertion of a thermometer pocket. A bellow is recommended on the distillate outlet DN1.

 

 

 
Industrial Glassware
Custom Made Glass
   

 

 

 
Copyright@Rainbow Scientifc Glass Industries. All Rights Reserved